Recent Posts

Need to meet NFPA 130 and Save Space in Transit Cars and Rolling Stock?

Posted by Jim Notarfrancesco on Feb 28, 2017 12:25:51 PM

Reduced Diameter Exane 15 Wire
Meets NFPA 130 for crowded locations

Today’s Transit Vehicles and Locomotives are more sophisticated requiring much more electronics which necessitate the use of more transit cables and wire. Cable trays, conduits and wire raceways have become very crowded. More space is needed in cabinets and wire panels to handle the increased number of transit cables and wires. Wire bundles and harnesses contain more wires and are larger than ever before. How can we bring these wire bundles down to size and reduce overall weight at the same time?

RSCC’s Exane 15 transit cable and wire is the answer to these problems. Exane 15 is a reduced diameter low voltage power, control and instrumentation wire for Rolling Stock applications in sizes 22 AWG to 10 AWG and available as both a single conductor and multi conductor configurations. It is a 600V 125C wire that employs a dual layer insulation system that meets the requirements of NFPA 130.

The use of Exane 15 will result in
1 - Weight savings of up to 30%
2 - Space Savings
         Up to 32% diameter reduction on wire bundles
         Up to 54% volume reduction in wire raceways and conduit fill.

Contact Us for Free Consultation

Read More

Topics: Exane Transit and rolling Stock data cables

Using NFPA 130 and AAR-S-501 compliant wire and cable for Rolling Stock and Transit Cars?

Posted by Jim Notarfrancesco on Oct 31, 2016 1:17:47 PM

You need to meet both NFPA 130 AND AAR-S-501 Transit Authority standards
to comply and ensure safety.

Specifiers of wire and cable in Transit Car electrical systems know that Vehicle Procurement Contracts let for the past five years require that wire and cable used in Rolling Stock must meet the NFPA 130 standard. But, in addition to the NFPA 130 standard, wire and cable also must meet additional physical and electrical requirements set by the Transit Authority.

The NFPA 130 standard requires wire and cable to meet the Underwriters Labs (UL) 1685 flame test (UL 1685 flame method is per IEEE 1202/FT4) and is primarily focused on 2 aspects of safety: Flame Spread and Smoke Generation. The primary purpose of the standard is to set limits to the spread of flame and also to set limits on the amount of smoke generated by the wire and cable once it comes into contact with the a fire. By setting these limits, the ability of the occupants of the vehicle to escape a fire event increases significantly.

However, it is important to note that NFPA 130 is not a stand-alone document for wire and cable performance in a Transit Vehicle application. It is an add-on to the Transit Authority base specification. The cable must be compliant to NFPA 130 and must also meet the other physical and electrical requirements of the Transit Authority Specification.  AAR-S-501 or RP-585 provide all the base requirements for wire and cable used by most Transit Authorities.   Cables should meet these requirements in addition to those specified in NFPA 130.  

Most current transit car procurement standards require compliance to NFPA 130 2014, however, the most current version available is NFPA 130 2017 (see web link below)

For your convenience, we are providing a summary of the AAR-S-501 or RP-585 key points by downloading a reference document

.DownLoad PDF file Here

Read More

Topics: Exane Transit and rolling Stock data cables